翻訳と辞書 |
Electric cell-substrate impedance sensing : ウィキペディア英語版 | Electric cell-substrate impedance sensing Electric cell-substrate impedance sensing or ECISTM (a trademark of Applied BioPhysics Inc.) refers to a non-invasive biophysical approach to monitor living animal cells ''in vitro'', i.e. within a well-defined laboratory environment.〔Giaever & Keese: A morphological biosensor for mammalian cells, ''Nature'' 366(1993)591-2〕 In ECIS the cells are grown on the surface of small and planar gold-film electrodes, which are deposited on the bottom of a cell culture dish (petri dish). The AC impedance of the cell-covered electrode is then measured at one or several frequencies as a function of time. Due to the insulating properties of their membranes the cells behave like dielectric particles so that the impedance increases with increasing coverage of the electrode until a confluent (i.e. continuous) layer of cells is established. In confluent cell layers the measured impedance is mainly determined by the three-dimensional shape of the cells. If cell shape changes occur, the current pathways through and around the cell bodies change as well, leading to a corresponding increase or decrease of impedance. Thus, by recording time-resolved impedance measurements, cell shape changes can be followed in real time with sub-microscopic resolution and can be used for bioanalytic purposes.〔Wegener, Zink, Roesen, Galla: Use of electrochemical impedance measurements to monitor b-adrenergic stimulation of bovine aortic endothelial cells. ''Eur. J. Physiol.'' 437/6(1999)925-934〕 As the shape of animal cells responds very sensitively to alterations in metabolism as well as chemical, biological or physical stimuli, the ECIS technique is applied in various experimental settings in cell biological research laboratories. It can be used as a sensor in cytotoxicity studies, drug development or as a non-invasive means to follow cell adhesion to ''in vitro'' surfaces.〔Wegener, Keese, Giaever: ECIS as a non-invasive means to follow the kinetics of cell spreading on artificial surfaces. ''Exp. Cell Res.'' 259(2000)158-166〕 Equipments based on the ECIS technique are also dedicated to monitor the chemokinetic activity of adherent cells spread on the electrode surface (micromotion) as well as their chemotactic activities in ECIS-based wound healing assays. == References ==
抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)』 ■ウィキペディアで「Electric cell-substrate impedance sensing」の詳細全文を読む
スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース |
Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.
|
|